{"product_id":"telemecanique-lt3sa00ed-thermistor-protection-relay-new-b118","title":"Telemecanique LT3SA00ED Thermistor Protection Relay (New) B118","description":"\u003c!-- oakmore-listing-design-v1 | adapted from established seller template --\u003e  \u003cdiv class=\"oakmore\"\u003e   \u003cimg class=\"oe-logo\" src=\"https:\/\/i.ebayimg.com\/00\/s\/MzAwWDMwMA==\/z\/5yEAAeSw7RNqmQ7x\/$_57.PNG?set_id=8800004005\" alt=\"Oakmore logo\"\u003e      \u003cdiv class=\"oe-intro\"\u003e\n\u003cdiv class=\"oe-kicker\"\u003eIndustrial controls and accessories\u003c\/div\u003e\n\u003ch1\u003eTelemecanique LT3SA00ED TeSys PTC Thermistor Protection Relay\u003c\/h1\u003e\n\u003cdiv class=\"oe-tags\"\u003e\u003cspan class=\"oe-tag oe-condition\"\u003eCondition: New\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"oe-grid\"\u003e\n\u003cdiv class=\"oe-gallery\"\u003e\n\u003cdiv class=\"oe-gallery-frame\"\u003e\u003cimg src=\"https:\/\/i.ebayimg.com\/images\/g\/w1kAAeSwvK1qsqDM\/s-l1600.webp\" alt=\"Actual LT3SA00ED stock box\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"oe-caption\"\u003eActual labelled stock box; please review all listing photographs.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"oe-specs\"\u003e\n\u003ch2\u003eAt a glance\u003c\/h2\u003e\n\u003ctable class=\"oe-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStock reference\u003c\/th\u003e\n\u003ctd\u003eB118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eTelemecanique \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMPN\u003c\/th\u003e\n\u003ctd\u003eLT3SA00ED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e24 or 48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReset\u003c\/th\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eContacts\u003c\/th\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEAN\u003c\/th\u003e\n\u003ctd\u003e3389110688207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eFrance (box label)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"oe-check\"\u003e\n\u003cstrong\u003eCheck the match before ordering\u003c\/strong\u003e\u003cp\u003eCheck the complete model number, electrical ratings, mounting and system requirements before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"oe-content\"\u003e\n\u003cdiv class=\"oe-section\"\u003e\n\u003ch2\u003eProduct details\u003c\/h2\u003e\n\u003cdiv class=\"oe-original-description\"\u003e\n\u003cp\u003eTelemecanique \/ Schneider Electric LT3SA00ED thermistor protection relay for monitoring compatible PTC temperature probes. This is the 24\/48 V DC version with automatic reset and 1 normally open plus 1 normally closed output contact.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModel LT3SA00ED; EAN 3389110688207 confirmed on the actual box.\u003c\/li\u003e\n\u003cli\u003e24 V or 48 V DC supply, using the appropriate connection terminals; check the manufacturer wiring diagram.\u003c\/li\u003e\n\u003cli\u003eAutomatic reset. Manufacturer trip resistance 2700–3100 ohms and reset resistance 1500–1650 ohms.\u003c\/li\u003e\n\u003cli\u003eUp to 6 compatible PTC probes; fault and voltage indication. Probes are not included.\u003c\/li\u003e\n\u003cli\u003eCage-type terminal connections; relay contact ratings depend on voltage and utilisation category.\u003c\/li\u003e\n\u003cli\u003eManufacturer dimensions: 100 mm high × 22.5 mm wide × 100 mm deep; net weight 0.22 kg. IP20.\u003c\/li\u003e\n\u003cli\u003eThe actual box label identifies France.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility and installation\u003c\/h3\u003e\n\u003cp\u003eQualified installation only. Thermistor protection relays provide supplemental motor protection and must be used with a conventional current-sensing overload relay. Isolate all supplies before wiring and match the 24\/48 V DC terminal arrangement, PTC probes and output-load ratings to the Schneider instructions. Automatic reset may allow equipment to restart when the fault clears; the overall machine control system must address this behaviour.\u003c\/p\u003e\n\u003ch3\u003eDelivery and returns\u003c\/h3\u003e\n\u003cp\u003eUK stock in Staffordshire. 60-day returns; buyer pays change-of-mind return postage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"oe-included\"\u003e\n\u003cstrong\u003eCondition \u0026amp; what is included\u003c\/strong\u003e\u003cp\u003eNew boxed stock. Actual packaging is photographed with visible age-related storage wear, creasing and marks. Internal relay and factory-seal status are not separately visible. One boxed relay is supplied per purchased quantity; PTC probes, wiring and other accessories are not promised.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n   \u003c\/div\u003e    \u003c\/div\u003e","brand":"Telemecanique","offers":[{"title":"Default Title","offer_id":55604457734482,"sku":"LT3SA00ED","price":145.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/2594\/2610\/files\/57_df0585f5-315e-4429-8e70-f981b82672f8.png?v=1795552129","url":"https:\/\/oakmoreglobal.com\/products\/telemecanique-lt3sa00ed-thermistor-protection-relay-new-b118","provider":"Oakmore Global","version":"1.0","type":"link"}