{"product_id":"telemecanique-lad8n11-tesys-side-auxiliary-contact-block-1no-1nc-new-b31","title":"Telemecanique LAD8N11 TeSys Side Auxiliary Contact Block 1NO 1NC (New) B31","description":"\u003c!-- oakmore-listing-design-v1 | item 377556225591 | original description backed up before revision --\u003e  \u003cdiv class=\"oakmore\"\u003e   \u003cimg class=\"oe-logo\" src=\"https:\/\/i.ebayimg.com\/00\/s\/MzAwWDMwMA==\/z\/5yEAAeSw7RNqmQ7x\/$_57.PNG?set_id=8800004005\" alt=\"Oakmore logo\"\u003e      \u003cdiv class=\"oe-intro\"\u003e     \u003cdiv class=\"oe-kicker\"\u003eContactor accessories\u003c\/div\u003e     \u003ch1\u003eTelemecanique LAD8N11 TeSys Side Auxiliary Contact Block 1NO 1NC (New) B31\u003c\/h1\u003e     \u003cdiv class=\"oe-tags\"\u003e\u003cspan class=\"oe-tag oe-condition\"\u003eCondition: New\u003c\/span\u003e\u003c\/div\u003e   \u003c\/div\u003e   \u003cdiv class=\"oe-grid\"\u003e     \u003cdiv class=\"oe-gallery\"\u003e\n\u003cdiv class=\"oe-gallery-frame\"\u003e\u003cimg src=\"https:\/\/i.ebayimg.com\/00\/s\/MTYwMFgxNjAw\/z\/GGoAAeSwLSZqx-0A\/$_57.PNG?set_id=880000500F\" alt=\"Telemecanique LAD8N11 TeSys Side Auxiliary Contact Block 1NO 1NC (New) B31\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"oe-caption\"\u003ePlease review all listing photographs before ordering.\u003c\/div\u003e\n\u003c\/div\u003e     \u003cdiv class=\"oe-specs\"\u003e       \u003ch2\u003eAt a glance\u003c\/h2\u003e       \u003ctable class=\"oe-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand \/ series\u003c\/th\u003e\n\u003ctd\u003eTelemecanique \/ Schneider Electric TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMPN\u003c\/th\u003e\n\u003ctd\u003eLAD8N11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGTIN \/ EAN\u003c\/th\u003e\n\u003ctd\u003e3389110384673\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFunction\u003c\/th\u003e\n\u003ctd\u003eInstantaneous auxiliary contact block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eContact arrangement\u003c\/th\u003e\n\u003ctd\u003e1 normally open + 1 normally closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting \/ connection\u003c\/th\u003e\n\u003ctd\u003eClip-on side mounting; screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThermal current (Ith)\u003c\/th\u003e\n\u003ctd\u003e10 A at 60°C; switching rating depends on voltage and load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated operating voltage\u003c\/th\u003e\n\u003ctd\u003eUp to 690 V AC, 25–400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExample switching ratings\u003c\/th\u003e\n\u003ctd\u003e6 A at 120 V AC-15; 1.04 A at 690 V AC-15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBody width\u003c\/th\u003e\n\u003ctd\u003e12.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCountry of manufacture\u003c\/th\u003e\n\u003ctd\u003eIndonesia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupplied quantity\u003c\/th\u003e\n\u003ctd\u003e1 auxiliary contact block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e       \u003cdiv class=\"oe-check\"\u003e\n\u003cstrong\u003eCheck the match before ordering\u003c\/strong\u003e\u003cp\u003eCheck the part number, specifications, condition and photographs against your requirements before ordering. See the product details below for any specific compatibility notes.\u003c\/p\u003e\n\u003c\/div\u003e     \u003c\/div\u003e   \u003c\/div\u003e   \u003cdiv class=\"oe-content\"\u003e     \u003cdiv class=\"oe-section\"\u003e\n\u003ch2\u003eProduct details\u003c\/h2\u003e\n\u003cdiv class=\"oe-original-description\"\u003e\n\u003cp\u003eTelemecanique LAD8N11 side-mounted auxiliary contact block for compatible TeSys contactors and control relays. It adds one normally open and one normally closed instantaneous contact for control and signalling circuits.\u003c\/p\u003e\n\u003cp\u003eCheck the exact contactor or relay reference and the side-mount interface before ordering. Catalogue compatibility includes TeSys LC1D and CAD models with AC coils; consult the appropriate manufacturer instructions for your base device. The 10 A figure is the thermal rating, not the switching capacity at every voltage.\u003c\/p\u003e\n\u003cp\u003eThe carton photographs show the available stock; the separate product reference image illustrates the type. Each purchase supplies one block, even where a group photograph shows more than one box.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"oe-included\"\u003e\n\u003cstrong\u003eCondition \u0026amp; what is included\u003c\/strong\u003e\u003cp\u003eOne new boxed auxiliary contact block per purchase. The box may have been opened and may show storage wear, labels or handwriting. No contactor, relay or additional accessories are included.\u003c\/p\u003e\n\u003c\/div\u003e     \u003c\/div\u003e        \u003c\/div\u003e    \u003c\/div\u003e","brand":"Telemecanique","offers":[{"title":"Default Title","offer_id":55601804345682,"sku":"IC081026-14-B31","price":11.09,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/2594\/2610\/files\/57_2d912b98-1c3e-4f88-a559-793c700f239b.png?v=1795539634","url":"https:\/\/oakmoreglobal.com\/products\/telemecanique-lad8n11-tesys-side-auxiliary-contact-block-1no-1nc-new-b31","provider":"Oakmore Global","version":"1.0","type":"link"}