{"product_id":"tdk-lambda-j10057-alpha-1000w-alpha1000-psu-new-b96","title":"TDK-Lambda J10057 Alpha 1000W alpha1000 PSU (New) B96","description":"\u003c!-- oakmore-listing-design-v1 | item 377020056541 | original description backed up before revision --\u003e  \u003cdiv class=\"oakmore\"\u003e   \u003cimg class=\"oe-logo\" src=\"https:\/\/i.ebayimg.com\/00\/s\/MzAwWDMwMA==\/z\/5yEAAeSw7RNqmQ7x\/$_57.PNG?set_id=8800004005\" alt=\"Oakmore logo\"\u003e      \u003cdiv class=\"oe-intro\"\u003e     \u003cdiv class=\"oe-kicker\"\u003eModular Switching Power Supplies\u003c\/div\u003e     \u003ch1\u003eTDK-Lambda J10057 Alpha 1000W alpha1000 PSU (New) B96\u003c\/h1\u003e     \u003cdiv class=\"oe-tags\"\u003e\u003cspan class=\"oe-tag oe-condition\"\u003eCondition: New\u003c\/span\u003e\u003c\/div\u003e   \u003c\/div\u003e   \u003cdiv class=\"oe-grid\"\u003e     \u003cdiv class=\"oe-gallery\"\u003e\n\u003cdiv class=\"oe-gallery-frame\"\u003e\u003cimg src=\"https:\/\/i.ebayimg.com\/images\/g\/0DYAAeSwHq9ptHf~\/s-l1600.jpg\" alt=\"TDK-Lambda J10057 Alpha 1000W alpha1000 PSU (New) B96\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"oe-caption\"\u003ePlease review all listing photographs before ordering.\u003c\/div\u003e\n\u003c\/div\u003e     \u003cdiv class=\"oe-specs\"\u003e       \u003ch2\u003eAt a glance\u003c\/h2\u003e       \u003ctable class=\"oe-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand \/ MPN\u003c\/th\u003e\n\u003ctd\u003eTDK-Lambda \/ J10057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRange\u003c\/th\u003e\n\u003ctd\u003eAlpha 1000 \/ CA1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration code\u003c\/th\u003e\n\u003ctd\u003eCA1000 BS_MFL 12C_CD 24G_CD 24G_CD 12C_CD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTotal chassis rating\u003c\/th\u003e\n\u003ctd\u003e1000 W maximum combined output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eC modules\u003c\/th\u003e\n\u003ctd\u003e2 × 12 V DC \/ 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eG modules\u003c\/th\u003e\n\u003ctd\u003e2 × 24 V DC \/ 25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput\u003c\/th\u003e\n\u003ctd\u003e85–264 V AC; 47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConstruction\u003c\/th\u003e\n\u003ctd\u003eEnclosed metal chassis; fan cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (D × W × H)\u003c\/th\u003e\n\u003ctd\u003e279 × 175.5 × 63 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eMade in the UK – label marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacture date shown\u003c\/th\u003e\n\u003ctd\u003e28 February 2024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStock reference\u003c\/th\u003e\n\u003ctd\u003eB96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e       \u003cdiv class=\"oe-check\"\u003e\n\u003cstrong\u003eCheck the match before ordering\u003c\/strong\u003e\u003cp\u003eCheck the part number, specifications, condition and photographs against your requirements before ordering. See the product details below for any specific compatibility notes.\u003c\/p\u003e\n\u003c\/div\u003e     \u003c\/div\u003e   \u003c\/div\u003e   \u003cdiv class=\"oe-content\"\u003e     \u003cdiv class=\"oe-section\"\u003e\n\u003ch2\u003eProduct details\u003c\/h2\u003e\n\u003cdiv class=\"oe-original-description\"\u003e\n\u003cp\u003eTDK-Lambda J10057 Alpha 1000 modular AC-DC power supply, with the configuration shown on the photographed nameplate. This unit contains two 12 V C modules and two 24 V G modules, plus the marked MFL option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput loading:\u003c\/strong\u003e the listed current values are individual module ratings. The combined load must remain within the 1000 W chassis limit and the applicable temperature derating; all modules cannot deliver their individual maximum power simultaneously.\u003c\/p\u003e\n\u003cp\u003eThe Alpha series provides regulated outputs with no minimum-load requirement, plus overvoltage, overcurrent, short-circuit and overtemperature protection. Operating range is 0–70°C; above 50°C, reduce total power and each output current by 2.5% per °C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e this component supply requires professional integration into suitable equipment. Disconnect mains before work, provide protective earth, maintain airflow and follow the TDK-Lambda instructions. Match J10057, the complete configuration, connectors and control options to the equipment; another Alpha 1000 configuration may have different outputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"oe-included\"\u003e\n\u003cstrong\u003eCondition \u0026amp; what is included\u003c\/strong\u003e\u003cp\u003eOne new TDK-Lambda J10057 power supply with the original carton shown. Packaging and the exterior may show storage or handling marks. Only the pictured unit is included; external wiring and mating connectors are not included. Dimensions refer to the PSU, not the packed parcel.\u003c\/p\u003e\n\u003c\/div\u003e     \u003c\/div\u003e        \u003c\/div\u003e    \u003c\/div\u003e","brand":"TDK-Lambda","offers":[{"title":"Default Title","offer_id":55601816568146,"sku":"e2ccf61ff31148749fd1f3d25d589938","price":419.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/2594\/2610\/files\/57_ac21b3e1-b5c9-4d2d-8309-ad2d8e843b05.png?v=1795539736","url":"https:\/\/oakmoreglobal.com\/products\/tdk-lambda-j10057-alpha-1000w-alpha1000-psu-new-b96","provider":"Oakmore Global","version":"1.0","type":"link"}