{"product_id":"hager-hda101u-mccb-h3-x160-tm-4x100a-18ka-new-open-box-b61","title":"Hager HDA101U MCCB h3 x160 TM 4x100A 18kA (New open box) B61","description":"\u003c!-- oakmore-listing-design-v1 | item 377032291370 | original description backed up before revision --\u003e  \u003cdiv class=\"oakmore\"\u003e   \u003cimg class=\"oe-logo\" src=\"https:\/\/i.ebayimg.com\/00\/s\/MzAwWDMwMA==\/z\/5yEAAeSw7RNqmQ7x\/$_57.PNG?set_id=8800004005\" alt=\"Oakmore logo\"\u003e      \u003cdiv class=\"oe-intro\"\u003e     \u003cdiv class=\"oe-kicker\"\u003eMoulded Case Circuit Breakers\u003c\/div\u003e     \u003ch1\u003eHager HDA101U MCCB h3 x160 TM 4x100A 18kA (New open box) B61\u003c\/h1\u003e     \u003cdiv class=\"oe-tags\"\u003e\u003cspan class=\"oe-tag oe-condition\"\u003eCondition: New – open box\u003c\/span\u003e\u003c\/div\u003e   \u003c\/div\u003e   \u003cdiv class=\"oe-grid\"\u003e     \u003cdiv class=\"oe-gallery\"\u003e\n\u003cdiv class=\"oe-gallery-frame\"\u003e\u003cimg src=\"https:\/\/i.ebayimg.com\/images\/g\/YOcAAeSw20xptGt-\/s-l1600.jpg\" alt=\"Hager HDA101U MCCB h3 x160 TM 4x100A 18kA (New open box) B61\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"oe-caption\"\u003ePlease review all listing photographs before ordering.\u003c\/div\u003e\n\u003c\/div\u003e     \u003cdiv class=\"oe-specs\"\u003e       \u003ch2\u003eAt a glance\u003c\/h2\u003e       \u003ctable class=\"oe-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand \/ MPN\u003c\/th\u003e\n\u003ctd\u003eHager \/ HDA101U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRange\u003c\/th\u003e\n\u003ctd\u003eh3 x160 TM A\/F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e4P4D; neutral N0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating voltage\u003c\/th\u003e\n\u003ctd\u003e220–415 V AC, 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd\u003e18 kA at 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThermal settings\u003c\/th\u003e\n\u003ctd\u003e63 \/ 80 \/ 100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (H × W × D)\u003c\/th\u003e\n\u003ctd\u003e130 × 100 × 68 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIP4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEAN\u003c\/th\u003e\n\u003ctd\u003e3250613130688\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003ePoland – carton marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStock reference\u003c\/th\u003e\n\u003ctd\u003eB61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e       \u003cdiv class=\"oe-check\"\u003e\n\u003cstrong\u003eCheck the match before ordering\u003c\/strong\u003e\u003cp\u003eCheck the part number, specifications, condition and photographs against your requirements before ordering. See the product details below for any specific compatibility notes.\u003c\/p\u003e\n\u003c\/div\u003e     \u003c\/div\u003e   \u003c\/div\u003e   \u003cdiv class=\"oe-content\"\u003e     \u003cdiv class=\"oe-section\"\u003e\n\u003ch2\u003eProduct details\u003c\/h2\u003e\n\u003cdiv class=\"oe-original-description\"\u003e\n\u003cp\u003eHager HDA101U h3 x160 four-pole moulded case circuit breaker (MCCB), rated 100 A. Its thermal-magnetic trip unit combines adjustable overload protection with fixed magnetic short-circuit protection.\u003c\/p\u003e\n\u003cp\u003eThe thermal setting is selectable at 0.63, 0.8 or 1 × rated current. Hager specifies 18 kA ultimate and service breaking capacity at 400 V AC; the carton identifies the 380–415 V AC rating. Four protected poles include configurable neutral protection N0–100%.\u003c\/p\u003e\n\u003cp\u003eFront screw-terminal connections accept 4–70 mm² flexible or 4–95 mm² rigid conductors. Rated insulation voltage is 690 V and impulse withstand is 8 kV. Dimensions above refer to the breaker, not the shipping package.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e a qualified electrician must verify the system fault level, coordination, neutral settings, enclosure and connection accessories. Isolate and prove dead before installation. Select the correct thermal setting for the circuit; this MCCB does not provide residual-current protection by itself.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"oe-included\"\u003e\n\u003cstrong\u003eCondition \u0026amp; what is included\u003c\/strong\u003e\u003cp\u003eOne Hager HDA101U circuit breaker, new in opened packaging. The carton shows storage wear. Please review all photographs; only the pictured item and accessories shown are included.\u003c\/p\u003e\n\u003c\/div\u003e     \u003c\/div\u003e        \u003c\/div\u003e    \u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":55602061836626,"sku":"9c6b085b9dae41ceafc19bf54d07fbc4","price":322.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/2594\/2610\/files\/57_5a33c7b1-7175-4b9f-9c0b-04c789cc6fe2.png?v=1795543215","url":"https:\/\/oakmoreglobal.com\/products\/hager-hda101u-mccb-h3-x160-tm-4x100a-18ka-new-open-box-b61","provider":"Oakmore Global","version":"1.0","type":"link"}